Summary for Test 2023-07-14-32-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993409 DEA: 07327604 EFIS: 0716000132 |
---|---|
DIST-CO-RTE-PM | 07-LA-39-32.2/38.4 |
Award Date | 03/07/2022 |
Closeout Date | Not set |
Work Description | INSTALL GUARDRAILS AND CONSTRUCT RETAINING WALLS. |
Location Description | LOS ANGELES COUNTY NEAR AZUSA AT VARIOUS LOCATIONS FROM 0.3 MILE SOUTH OF NORTH FORK SAN GABRIEL RIVER OVERCROSSING TO 0.3 MILE NORTH CRYSTAL LAKE ROAD |
QA Service Level | 1 (Verified on 12/06/2021) |
Sample Information
Sample Taken Date | 07/14/2023 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/8" HMA DIKE 421500 |
The quantity of what the sample constitutes | 40 tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cesar | Last name of sampler or witnessed by | Gomez |
Title of sampler | Vulcan Irwindale QC | Telephone number of sampler | |
Laboratory sample identification | 23-274 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Irwindale | Transportation Laboratory (TL) Number | 0714A2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/8 inch | Lot number | |
Sublot number | HMA Mix Number | 421500 |
Test Details
DIME Sample ID: 2023-07-14-32
DIME Test ID: 2023-07-14-32-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-07-24
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Philip Maquiran
Date of test: 07/24/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4007.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 5539.5 g
Mass of HMA Sample prior to ignition: 1532.3 g
Mass Loss: 99.0 g
Mass of aggregate remaining after ignition: 1433.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.46 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/24/2023 ✔