Summary for Test 2023-07-18-12-2
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 993715 DEA: 010G1404 EFIS: 0116000129 |
---|---|
DIST-CO-RTE-PM | 01-HUM-96,169-VAR |
Award Date | 11/16/2022 |
Closeout Date | Not set |
Work Description | HUM 96-169 5 Bridges Rail Upgrade (Do not include in project name: STRUCTURAL STEEL, CONCRETE BARRIER, POLYESTER CONCRETE OVERLAY) |
Location Description | HUMBOLDT COUNTY ON ROUTES 96 AND 169 AT VARIOUS LOCATIONS (Bridge Nos. 04-0215, 04-0059, 04-0063, 04-0225, 04-0061) |
QA Service Level | 1 (Verified on 04/19/2022) |
Sample Information
Sample Taken Date | 07/18/2023 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2023 |
Sample type | Quality Assurance | A brief description of the sample | F3125 Gr A325 Bolts |
The quantity of what the sample constitutes | 905 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Duben | Last name of sampler or witnessed by | Duckworth |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson Industries | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1000118423 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM F3125 Gr A325 | |
Bolt Length(s) | 3" | Nut Specification | NA |
Washer Specification | NA | Finish | |
Diameter/Size | 1 | Bolt Mfg. Lot Number | W000057938 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2023-07-18-12
DIME Test ID: 2023-07-18-12-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2023-07-27
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 07/24/2023
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1B | W000057938 | 1.0000 | 82421 | 366.63 | 10.00 | Wedge Tensile | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 7/27/2023 ✔