Summary for Test 2023-05-16-62-10

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994266
DEA: 070W3604
EFIS: 0722000007
DIST-CO-RTE-PM07-LA-14,126-R30.9,R4.1
Award Date11/16/2022
Closeout DateNot set
Work DescriptionPOLYESTER CONCRETE OVERLAY AND JOINT SEAL REPLACEMENT.
Location DescriptionLOS ANGELES COUNTY NEAR SANTA CLARITA ON ROUTE 14 AT VIA PRINCESSA UNDERCROSSING AND ON ROUTE 126 AT CASTAIC CREEK BRIDGE.
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date05/16/2023 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2023
Sample typeVerification A brief description of the sample2 Bags of each Bin Agg. (1,2,3,4), 1 Bag of RAP:
The quantity of what the sample constitutesPSUE 1/2" WMA-A-SP R15 0.25% EVO From where was the sample collectedManufacturer
First name of sampler or witnessed byThomas Last name of sampler or witnessed by Shivens QC
Title of sampler Telephone number of sampler
Laboratory sample identification0293A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials Sun Valley
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number320914 SVA LTR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-05-16-62
DIME Test ID: 2023-05-16-62-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-09-07

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Satish Jain/M. Campos
Date of test: 06/13/2023
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 98 %
Cumulative percent passing the 3/8 in. sieve: 88 %
Cumulative percent passing the #4 sieve: 61 %
Cumulative percent passing the #8 sieve: 39 %
Cumulative percent passing the #16 sieve: 25 %
Cumulative percent passing the #30 sieve: 17 %
Cumulative percent passing the #50 sieve: 10 %
Cumulative percent passing the #100 sieve: 6 %
Cumulative percent passing the #200 sieve: 3.4 %
General comments (publicly viewable) (Max 1000 characters): Comb. Agg. Gradation W/Rap Gradation Correlation Factors

Test was verified on 9/7/2023