Summary for Test 2023-05-16-62-4

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 994266
DEA: 070W3604
EFIS: 0722000007
DIST-CO-RTE-PM07-LA-14,126-R30.9,R4.1
Award Date11/16/2022
Closeout DateNot set
Work DescriptionPOLYESTER CONCRETE OVERLAY AND JOINT SEAL REPLACEMENT.
Location DescriptionLOS ANGELES COUNTY NEAR SANTA CLARITA ON ROUTE 14 AT VIA PRINCESSA UNDERCROSSING AND ON ROUTE 126 AT CASTAIC CREEK BRIDGE.
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date05/16/2023 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2023
Sample typeVerification A brief description of the sample2 Bags of each Bin Agg. (1,2,3,4), 1 Bag of RAP:
The quantity of what the sample constitutesPSUE 1/2" WMA-A-SP R15 0.25% EVO From where was the sample collectedManufacturer
First name of sampler or witnessed byThomas Last name of sampler or witnessed by Shivens QC
Title of sampler Telephone number of sampler
Laboratory sample identification0293A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials Sun Valley
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number320914 SVA LTR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-05-16-62
DIME Test ID: 2023-05-16-62-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2023-09-07

Test Results


Input Type: Measured
Tester's full name: Ali Rehman
Date of test: 06/12/2023
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4678 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3617 grams
Percent loss after 100 revolutions: 6 %
Percent loss after 500 revolutions: 28 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/7/2023