Summary for Test 2023-06-14-62-9
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/14/2023 | Sample Unique Key | 62 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2023 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1"x#4 concrete aggregate |
The quantity of what the sample constitutes | Three Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Mathew | Last name of sampler or witnessed by | Valdivia |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | 2023-06-14-47 | |
The fabricator/manufacturer/facility name | Vulcan Materials San Bernardino | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0137 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-06-14-62
DIME Test ID: 2023-06-14-62-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2023-07-25
Test Results
Describe the gradation of the aggregate or the test method:: Mix of sizes - max 1.5 in.
Input Type: Calculated
Tester's full name: Marta Landaverde
Date of test: 07/05/2023
Cleanness value (11/2 in. maximum aggregate mix): 91
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/25/2023 ✔