Summary for Test 2023-07-21-16-2
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 212720 DEA: 07291404 EFIS: 0712000094 |
---|---|
DIST-CO-RTE-PM | 07-LA-1-55-58 |
Award Date | 02/18/2021 |
Closeout Date | Not set |
Work Description | TRANCAS CREEK BRIDGE REPLACEMENT |
Location Description | IN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027). |
QA Service Level | 1 (Verified on 04/02/2021) |
Sample Information
Sample Taken Date | 07/21/2023 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1" X #4 |
The quantity of what the sample constitutes | 80 CY | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Hopkins |
Title of sampler | Plant Inspector | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Associated Ready Mix - Oxnard | Transportation Laboratory (TL) Number | C072123A |
Inspector Lot Number from the Transportation Laboratory (TL) Form | KH105E | Structure unique identifier | |
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0054 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | Associated RM Oxnard | A detailed description of where the material sample was collected | Conveyor Belt |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | SL675350SP | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-07-21-16
DIME Test ID: 2023-07-21-16-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2023-07-21
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 07/21/2023
Top sediment column reading (single primary size): 0.4 in
Cleanness value (single primary size): 89
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2023 ✔