Summary for Test 2023-06-26-76-2

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994087
DEA: 051G4104
EFIS: 0515000012
DIST-CO-RTE-PM05-SB-101-4.0/4.8
Award Date08/01/2022
Closeout DateNot set
Work DescriptionSanta Claus Lane Bike Path - !!Charge time to 05-0N72U4 per Project Manager / Corridor Manager!!
Location Description!!Charge time to 05-0N72U4 per Project Manager / Corridor Manager!!
QA Service Level1 (Verified on 07/25/2022)

Sample Information

Sample Taken Date06/26/2023 Sample Unique Key76
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2023
Sample typeAcceptance A brief description of the samplemicro seal emulsion
The quantity of what the sample constitutes2 quart bottles From where was the sample collectedJob Site
First name of sampler or witnessed byTom Last name of sampler or witnessed byCromwell
Title of samplerconsultant Telephone number of sampler
Laboratory sample identificationBP0004 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeMSE
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2023-06-26-76
DIME Test ID: 2023-06-26-76-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2023-07-17

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 07/17/2023
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 144.1 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 112.5 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 143.2 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 111.6 g
Beaker 1 Residue: 63.2 %
Beaker 2 Residue: 63.2 %
Percentage of residue: 63 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/17/2023