Summary for Test 2023-07-13-12-4

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 994753
DEA: 061E8404
EFIS: 0622000104
DIST-CO-RTE-PM06---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date07/13/2023 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2023
Sample typeDepartment Acceptance A brief description of the sampleISR-RSC Beams
The quantity of what the sample constitutes15 CY From where was the sample collectedJob Site
First name of sampler or witnessed byNeale Last name of sampler or witnessed byBrown
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS SHORT LOAD RAPID SET Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCTS-65-GBR
The truck number from where the sample was collected15 The batch plant ticket number from where the sample was collected3
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of truck discharge chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-07-13-12
DIME Test ID: 2023-07-13-12-4
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2023-07-17

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: James Watson
Date of test: 07/17/2023
Identification number: 60
Width of specimen: 6.0625 inch
Width of specimen 2: 6.125 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6.125 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 6510 lb
Maximum load applied 2: 6650 lb
Maximum load applied 3: 6610 lb
Curing history and apparent moisture condition of the specimen: Good
If specimen was capped, ground or if leather shims were used: leather shims were used
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 540 psi
Modulus of rupture 2: 560 psi
Modulus of rupture 3: 550 psi
Modulus of rupture average: 550 psi
General comments (publicly viewable) (Max 1000 characters): 3 days MOR

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-0Q9204_37087_220713_60_3Dpdf108.56 KB07/17/20232023-07-13-12-4   Info

Test was verified on 7/17/2023