Summary for Test 2023-07-05-31-3

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994155
DEA: 072XA504
EFIS: 0722000359
DIST-CO-RTE-PM07-LA-91-11.65
Award Date07/05/2022
Closeout Date03/05/2024
Work DescriptionBridge Repair
Location DescriptionNot set
QA Service Level1 (Verified on 07/28/2022)

Sample Information

Sample Taken Date07/05/2023 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/06/2023
Sample typeAcceptance A brief description of the sample1x4 and WCS
The quantity of what the sample constitutes40 cy From where was the sample collectedManufacturer
First name of sampler or witnessed byvictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler2137924794
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAssociated Signal Hill Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Orca Quarry Port McNeill BC Canada)
The fabricator's/manufacturer's product name for the sampleDeck pour The fabricator/manufacturer designation for the sample
The plant numbersignal hill A detailed description of where the material sample was collectedStorage Bin
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberOR572SRP3F Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-05-31
DIME Test ID: 2023-07-05-31-3
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-07-20

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 07/06/2023
Cumulative Mass RetainedCumulative Percent Passing
511 grams
0 grams100 %
9 grams98 %
85 grams83 %
172 grams66 %
269 grams47 %
399 grams22 %
475 grams7 %
499 grams2 %
501 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/20/2023