Summary for Test 2023-06-23-35-1
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214670 DEA: 07331004 EFIS: 0716000220 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-9.0/9.2 |
Award Date | 04/13/2022 |
Closeout Date | Not set |
Work Description | CONCRETE SLAB REPLACEMENT & GRIND, PAVEMENT & RESURFACE ACE |
Location Description | VENTURA COUNTY IN THOUSAND OAKS FROM NORTHBOUND OFF-RAMP TO SOUTHBOUND OFF-RAMP AT CONEJO COMMERCIAL VEHICLE ENFORCEMENT FACILITIES |
QA Service Level | 1 (Verified on 07/12/2021) |
Sample Information
Sample Taken Date | 06/23/2023 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/24/2023 |
Sample type | Department Acceptance | A brief description of the sample | LCB |
The quantity of what the sample constitutes | 100 cu. yd. | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Philip | Last name of sampler or witnessed by | Maquiran |
Title of sampler | MREA | Telephone number of sampler | (213) 358-1518 |
Laboratory sample identification | 23-0893 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Powell | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | S30C396L0A |
---|---|---|---|
The truck number from where the sample was collected | 20030 | The batch plant ticket number from where the sample was collected | 192619 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Discharge concrete chute into wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-06-23-35
DIME Test ID: 2023-06-23-35-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-06-30
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 06/30/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 15982 lb
Maximum load on cylinder 2: 16189 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 24.86 in^2
Compressive strength (to nearest 10 psi): 570 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/30/2023 ✔