Summary for Test 2023-05-18-103-1
Test performed: CONCLP 2-16Project Information
Project Identifiers | Project ID: 215188 DEA: 080F5434 EFIS: 0817000239 Permit Numbers: 0823NMC0369 |
---|---|
DIST-CO-RTE-PM | 08-RIV-I-15,SR-91-6.1-7.6 |
Award Date | 03/11/2020 |
Closeout Date | Not set |
Work Description | I-15 ELC: 15/91 Express Lanes Connector Project (ELC) |
Location Description | Junction of I-15 and SR-91 in Corona, CA |
QA Service Level | 1 (Verified on 09/16/2020) |
Sample Information
Sample Taken Date | 05/18/2023 | Sample Unique Key | 103 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/18/2023 |
Sample type | Quality Assurance | A brief description of the sample | Rapid Set |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | BASF | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Rapid Set | Manufacturer | BASF |
---|---|---|---|
Mix no. | 3730 | Materials Received | Master Emaco T545 |
Lot no. | 2J30743081 | Batch no. | 2J30743081 |
Test Details
DIME Sample ID: 2023-05-18-103
DIME Test ID: 2023-05-18-103-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 2-16: Rapid Set Patching Materials
Test Release Date: 2023-06-30
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 06/14/2023
Compressive Strength @ 3 hrs (CTM 551): 4030
Compressive Strength @ 24 hrs (CTM 551): 6020
Flexure Strength @ 24 hrs (CTM 551): 0
Bond Strength @ 24 hrs - SSD (CTM 551): 0
Bond Strength @ 24 hrs - Dry (CTM 551): 0
Water Absorption (CTM 551): 0
Abrasion @ 24 hrs (CTM 550): 24
Drying Shrinkage @ 4 days (CTM 596): 0
Soluble Chlorides (CTM 422): 0.0063
Water Soluble-Sulfates (CTM 417): 0.0724
Material Weight: 50
Water Weight: 4.17
General comments (publicly viewable) (Max 1000 characters): Sulfates and chlorides accepted on previous sample results.
Test was verified on 6/30/2023 ✔