Summary for Test 2023-06-20-10-6

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 994399
DEA: 09378704
EFIS: 0919000001
DIST-CO-RTE-PM09-MNO-395-55.5/58.2
Award Date12/22/2022
Closeout Date12/22/2023
Work DescriptionPARTIAL DEPTH RECYCLE AND HMA (TYPE A).
Location DescriptionMONO COUNTY NEAR LEE VINING FROM 0.2 MILE SOUTH OF CEMETERY ROAD TO ROUTE 167
QA Service Level1 (Verified on 07/31/2023)

Sample Information

Sample Taken Date06/20/2023 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2023
Sample typeVerification A brief description of the sample3/4" HMA A SP
The quantity of what the sample constitutes32 Boxes of HMA From where was the sample collectedManufacturer
First name of sampler or witnessed byJosh Last name of sampler or witnessed byHubartt
Title of samplerTET Telephone number of sampler7609373217
Laboratory sample identificationJMF 3 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Lee Vining Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number

Test Details

DIME Sample ID: 2023-06-20-10
DIME Test ID: 2023-06-20-10-6
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2023-06-29

Test Results


Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 06/27/2023
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 15000
Specified number of passes at inflection point: 12500
Type and Amount of Anti-Stripping Additive: 0.5%
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 122 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 2.23 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 2.33 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 15000
Impression at specified number of passes average: 2 mm
General comments (publicly viewable) (Max 1000 characters): JMF-03

Test was verified on 6/29/2023