Summary for Test 2023-05-09-53-2

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date05/09/2023 Sample Unique Key53
Date that the sample was received by the laboratory/organization performing the testing05/11/2022 Sample typeQuality Assurance
A brief description of the sampleCONCRETE CYLINDERS The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byAleksey
Last name of sampler or witnessed bySouglobov Title of samplerQA Atlas
Telephone number of sampler Laboratory sample identification1026-509
Linked DIME Sample ID The fabricator/manufacturer/facility nameMyers - Rados Joint Venture
Transportation Laboratory (TL) Number2 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610887 w fiber
The truck number from where the sample was collected66581 The batch plant ticket number from where the sample was collected42789931
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedExisting EB 91 Express Lane Above RR Tracks Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-05-09-53
DIME Test ID: 2023-05-09-53-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-06-28

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Ali Rehman
Date of test: 06/20/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 176280 lb
Maximum load on cylinder 2: 174710 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 6235.6 psi
Compressive strength of cylinder 2: 6180.0 psi
Compressive strength (to nearest 10 psi): 6210 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/28/2023