Summary for Test 2023-05-22-45-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/22/2023 | Sample Unique Key | 45 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/30/2023 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 1 X 4 Concrete Aggregates |
The quantity of what the sample constitutes | Production Stockpile | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Travis | Last name of sampler or witnessed by | Brewer |
Title of sampler | Technician | Telephone number of sampler | 530-491-1042 |
Laboratory sample identification | 23-APPC-0095 | Linked DIME Sample ID | 2023-05-22-29 |
The fabricator/manufacturer/facility name | Western Aggregates | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-58-0001 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-05-22-45
DIME Test ID: 2023-05-22-45-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-06-27
Test Results
What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 06/01/2023
Individual Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
12000.8 grams | ||||||
0 grams | 100 % | |||||
0 grams | 100 % | |||||
2096.8 grams | 83 % | |||||
5347.6 grams | 38 % | |||||
3035.4 grams | 13 % | |||||
1300.6 grams | 2 % | |||||
147.8 grams | 1 % | |||||
62.3 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/27/2023 ✔