Summary for Test 2023-04-16-6-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215150 DEA: 120P0304 EFIS: 1215000024 |
---|---|
DIST-CO-RTE-PM | 12-ORA-74-11.5/16.6 |
Award Date | 11/13/2020 |
Closeout Date | Not set |
Work Description | PLACE HIGH FRICTION SURFACE TREATMENT, HMA & MIDWEST GUARDRAIL SYSTEM. |
Location Description | ORANGE COUNTY NEAR SAN JUAN CAPISTRANO FROM 1.0 MILE WEST OF SAN JUAN HOT SPRINGS ROAD TO ORANGE COUNTY LINE |
QA Service Level | 1 (Verified on 12/10/2020) |
Sample Information
Sample Taken Date | 04/16/2023 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA-A |
The quantity of what the sample constitutes | HMA boxes, agg, RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Nguyen |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 23-0309 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | RJ Noble Orange | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2023-04-16-6
DIME Test ID: 2023-04-16-6-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-06-21
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 05/25/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3952.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 6039.4 g
Mass of HMA Sample prior to ignition: 2086.7 g
Mass Loss: 107.3 g
Mass of aggregate remaining after ignition: 1979.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.07 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.07 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
2023AC-SP-0018 | 104.59 KB | 06/21/2023 | 2023-04-16-6-1 | Info |
Test was verified on 6/21/2023 ✔