Summary for Test 2023-06-09-32-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994514 DEA: 043Y0504 EFIS: 0423000192 |
---|---|
DIST-CO-RTE-PM | 04-SOL-12112113-var/var |
Award Date | 01/12/2023 |
Closeout Date | 03/11/2024 |
Work Description | PAVEMENT REPAIR |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/09/2023 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/13/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA Type A |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Plant QC | Last name of sampler or witnessed by | Plant QC |
Title of sampler | QC Technician | Telephone number of sampler | |
Laboratory sample identification | Con_23_675 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Granite Bradshaw Plant | Transportation Laboratory (TL) Number | C726063 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 2 |
Sublot number | 1 | HMA Mix Number | 1635V |
Test Details
DIME Sample ID: 2023-06-09-32
DIME Test ID: 2023-06-09-32-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-06-16
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Augusto Rios
Date of test: 06/13/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2157.0 g
Mass Loss: 110.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.50 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.50 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/16/2023 ✔