Summary for Test 2023-06-15-1-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993208 DEA: 034F38U4 EFIS: 0321000092 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-16.2/25.8 |
Award Date | 11/04/2021 |
Closeout Date | Not set |
Work Description | WIDEN SHOULDERS AND IMPROVE CLEAR RECOVERY ZONE. |
Location Description | YUBA COUNTY NEAR MARYSVILLE FROM 0.2 MILE NORTH OF LAURELLEN ROAD TO SOUTH HONCUT CREEK BRIDGE |
QA Service Level | 1 (Verified on 09/10/2021) |
Sample Information
Sample Taken Date | 06/15/2023 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4"HMA-A |
The quantity of what the sample constitutes | boxes of mix | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ? | Last name of sampler or witnessed by | ? |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | DeSilva Gates - Marysville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 3 |
Sublot number | 7 | HMA Mix Number |
Test Details
DIME Sample ID: 2023-06-15-1
DIME Test ID: 2023-06-15-1-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-06-15
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 06/15/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2230.0 g
Mass Loss: 121.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.48 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.98 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/15/2023 ✔