Summary for Test 2023-06-14-31-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994294 DEA: 07204904 EFIS: 0717000022 |
---|---|
DIST-CO-RTE-PM | 07-LA-405-39.1 |
Award Date | 12/12/2022 |
Closeout Date | Not set |
Work Description | WIDEN THE ON-RAMP AND MODIFY ELECTRICAL SYSTEM. |
Location Description | THE CITY AND COUNTY OF LOS ANGELES AT VENTURA BOULEVARD ON RAMP |
QA Service Level | 1 (Verified on 10/06/2022) |
Sample Information
Sample Taken Date | 06/14/2023 | Sample Unique Key | 31 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/14/2023 |
Sample type | Acceptance | A brief description of the sample | Subgrade |
The quantity of what the sample constitutes | 85 sq. yd. approx. | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Philip | Last name of sampler or witnessed by | Maquiran |
Title of sampler | MREA | Telephone number of sampler | 12133581518 |
Laboratory sample identification | 23-0844 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Powell General Engineering Contractor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | From various locations at subgrade. | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-06-14-31
DIME Test ID: 2023-06-14-31-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-06-15
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 06/14/2023
Sum of Count or Density: 5.68 g/cc
Average of Count or Density: 1.89 g/cc
Sum of Moisture Count: 0.87 g/cc
Average of Moisture Count: 0.29 g/cc
Calculated Percent Relative Compaction: 92.6 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/15/2023 ✔