Summary for Test 2023-06-05-12-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994090
DEA: 01434804
EFIS: 0100000672
DIST-CO-RTE-PM01-MEN-1-62.0/62.3
Award Date10/21/2022
Closeout DateNot set
Work DescriptionPudding Creek Bridge Widening
Location DescriptionMENDOCINO COUNTY IN FORT BRAGG FROM ELM STREET TO PUDDING CREEK ROAD 421
QA Service Level1 (Verified on 07/11/2022)

Sample Information

Sample Taken Date06/05/2023 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/06/2023
Sample typeQuality Control A brief description of the sample1cubic ft. of Concrete for Testing
The quantity of what the sample constitutes1cubic ft. of Concrete for Testing From where was the sample collectedFabricator
First name of sampler or witnessed byMark Patrick Last name of sampler or witnessed byBaddu
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberVER-85LV
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected8684
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBed 2, 3rd Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-06-05-12
DIME Test ID: 2023-06-05-12-1
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-06-08

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ferdinand Rosal
Date of test: 06/06/2023
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 8.84 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 54420 lb
Maximum load on cylinder 2: 55585 lb
Maximum load on cylinder 3: 56355 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 1 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.56 in^2
Cross sectional area of cylinder 2: 12.56 in^2
Cross sectional area of cylinder 3: 12.56 in^2
Compressive strength (to nearest 10 psi): 4420 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/8/2023