Summary for Test 2023-05-17-18-4

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993715
DEA: 010G1404
EFIS: 0116000129
DIST-CO-RTE-PM01-HUM-96,169-VAR
Award Date11/16/2022
Closeout DateNot set
Work DescriptionHUM 96-169 5 Bridges Rail Upgrade (Do not include in project name: STRUCTURAL STEEL, CONCRETE BARRIER, POLYESTER CONCRETE OVERLAY)
Location DescriptionHUMBOLDT COUNTY ON ROUTES 96 AND 169 AT VARIOUS LOCATIONS (Bridge Nos. 04-0215, 04-0059, 04-0063, 04-0225, 04-0061)
QA Service Level1 (Verified on 04/19/2022)

Sample Information

Sample Taken Date05/17/2023 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/18/2023
Sample typeQuality Assurance A brief description of the samplePCC Cylinders
The quantity of what the sample constitutes10 Cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byJoe Last name of sampler or witnessed byPedrori
Title of samplerASR Telephone number of sampler
Laboratory sample identificationC0155 Linked DIME Sample ID
The fabricator/manufacturer/facility namenot provided Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberE400 FBR
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectednot provided
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-05-17-18
DIME Test ID: 2023-05-17-18-4
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-06-07

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jamie Kelley
Date of test: 06/07/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 118170 lb
Maximum load on cylinder 2: 122970 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 21 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 4270 psi
General comments (publicly viewable) (Max 1000 characters): 21 Day Test

Test was verified on 6/7/2023