Summary for Test 2023-06-02-3-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214998
DEA: 044H0504
EFIS: 0413000080
DIST-CO-RTE-PM04-SON-12-25.8-33.3
Award Date07/29/2022
Closeout DateNot set
Work DescriptionBRIDGE SCOUR MITIGATION
Location DescriptionSONOMA COUNTY NEAR SANTA ROSA AT SONOMA CREEK BRIDGE AND AT HOOKER CREEK BRIDGE
QA Service Level1 (Verified on 09/10/2020)

Sample Information

Sample Taken Date06/02/2023 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/06/2023
Sample typeQuality Assurance A brief description of the sampleWelded Hoops
The quantity of what the sample constitutes398 From where was the sample collectedFabricator
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Telephone number of sampler2134354055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-065-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4126990
Hoop Manufacturer Lot Number(s)15 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyCMC Rebar San Bernardino Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-06-02-3
DIME Test ID: 2023-06-02-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-06-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 06/07/2023
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13156/19mm0.4443047.5197835Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 6/7/2023