Summary for Test 2023-06-01-9-1

Test performed: ASTM A370-20

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date06/01/2023 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/01/2023
Sample typeAuthorization A brief description of the sample19 strand anchor head
The quantity of what the sample constitutesOne anchor head From where was the sample collectedSupplier
First name of sampler or witnessed byDavid Last name of sampler or witnessed byMurray
Title of sampler Telephone number of sampler9166395549
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFarrar Corporation Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)I212
Part Number (s)02AH0038 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Farrar Corporation
Prestressing ManufacturerSumiden

Test Details

DIME Sample ID: 2023-06-01-9
DIME Test ID: 2023-06-01-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2023-07-12

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 06/06/2023
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
10.2520.04988648401081186.5aauvinen
20.2510.04948632011073307.4aauvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 7/12/2023