Summary for Test 2023-05-09-101-5
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/09/2023 | Sample Unique Key | 101 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/23/2023 |
Sample type | Verification | A brief description of the sample | 1/2" HMA-A |
The quantity of what the sample constitutes | 24 Boxes HMA, 4 Qts Binder | From where was the sample collected | Source |
First name of sampler or witnessed by | Allen | Last name of sampler or witnessed by | Oliver |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | 023-023 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | SPM-Avenal | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2023-05-09-101
DIME Test ID: 2023-05-09-101-5
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-06-05
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Glenn Bradley
Date of test: 06/05/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1,706.2 g
Mass Loss: 114.6 g
Correction Factor (Percent by mass of HMA Specimen): 1.23 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.21 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.28 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2023 ✔