Summary for Test 2023-05-17-18-3
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 993715 DEA: 010G1404 EFIS: 0116000129 |
---|---|
DIST-CO-RTE-PM | 01-HUM-96,169-VAR |
Award Date | 11/16/2022 |
Closeout Date | Not set |
Work Description | HUM 96-169 5 Bridges Rail Upgrade (Do not include in project name: STRUCTURAL STEEL, CONCRETE BARRIER, POLYESTER CONCRETE OVERLAY) |
Location Description | HUMBOLDT COUNTY ON ROUTES 96 AND 169 AT VARIOUS LOCATIONS (Bridge Nos. 04-0215, 04-0059, 04-0063, 04-0225, 04-0061) |
QA Service Level | 1 (Verified on 04/19/2022) |
Sample Information
Sample Taken Date | 05/17/2023 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/18/2023 |
Sample type | Quality Assurance | A brief description of the sample | PCC Cylinders |
The quantity of what the sample constitutes | 10 Cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Pedrori |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | C0155 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | not provided | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | E400 FBR |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | not provided | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | CHUTE FROM TRUCK | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-05-17-18
DIME Test ID: 2023-05-17-18-3
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-05-31
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jamie Kelley
Date of test: 05/31/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 109920 lb
Maximum load on cylinder 2: 110490 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 14 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3,888.2 psi
Compressive strength of cylinder 2: 3,908.4 psi
Compressive strength (to nearest 10 psi): 3900 psi
General comments (publicly viewable) (Max 1000 characters): 14 Day Test
Test was verified on 5/31/2023 ✔