Summary for Test 2023-04-28-6-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/28/2023 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/03/2023
Sample typeRecertification A brief description of the sample#8 5'-2" dia.
The quantity of what the sample constitutes15 From where was the sample collectedFabricator
First name of sampler or witnessed byAdrian Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-157-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)069222
Hoop Manufacturer Lot Number(s)L-3 Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-04-28-6
DIME Test ID: 2023-04-28-6-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2023-07-07

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 05/25/2023
UTM: 400kip
Temperature: 72.00 f
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
14No. 8/25mmL-30.797691697362100 Cycle-4aauvinen

General comments (publicly viewable) (Max 1000 characters): 100 Cycle-4
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 7/7/2023