Summary for Test 2023-05-13-7-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 212880
DEA: 050F9704
EFIS: 0513000017
DIST-CO-RTE-PM05-MON-101-62.7
Award Date03/17/2022
Closeout Date02/14/2024
Work DescriptionN. SOLEDAD OH DECK REPLACEMENT
Location DescriptionON RTE 101 IN MONTEREY COUNTY NEAR SOLEDAD AT THE NORTH SOLEDAD OH BRIDGE BR 44-0091L/R
QA Service Level1 (Verified on 09/30/2019)

Sample Information

Sample Taken Date05/13/2023 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/23/2023
Sample typeDepartment Acceptance A brief description of the sampleSS-1H Tack Coat ASPHALTIC EMULSION
The quantity of what the sample constitutes1 bottle of emulsion From where was the sample collectedJob Site
First name of sampler or witnessed byA Last name of sampler or witnessed byRamirez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Northwest Oil - Stockton, CA Transportation Laboratory (TL) NumberC0513231
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2023-05-13-7
DIME Test ID: 2023-05-13-7-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2023-05-24

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Humberto Ramirez
Date of test: 05/24/2023
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 146.6 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 117.3 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 144.2 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 114.9 g
Beaker 1 Residue: 58.6 %
Beaker 2 Residue: 58.6 %
Percentage of residue: 59 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/24/2023