Summary for Test 2023-04-27-64-6

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 214336
DEA: 07302404
EFIS: 0713000488
DIST-CO-RTE-PM07-VEN-101-37/40
Award DateNot set
Closeout DateNot set
Work DescriptionPADRE JUAN REHAB
Location DescriptionVEN 101
QA Service Level1 (Verified on 02/26/2021)

Sample Information

Sample Taken Date04/27/2023 Sample Unique Key64
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/03/2023
Sample typePer Request A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byAvo Last name of sampler or witnessed byKarajian
Title of sampler Telephone number of sampler
Laboratory sample identification0231-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite-Santa Paula Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-04-27-64
DIME Test ID: 2023-04-27-64-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2023-05-30

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Sm Ali
Date of test: 05/16/2023
Time of test: 6:05 HH:MM
Test Temperature: 135 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 56 %
Viscosity reading #1 (A) : 0.284 Pa-s
Viscosity reading #2 (B) : 0.281 Pa-s
Viscosity reading #3 (C): 0.287 Pa-s
Average viscosity: 0.284 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/30/2023