Summary for Test 2023-05-15-32-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214451 DEA: 07303704 EFIS: 0714000035 |
---|---|
DIST-CO-RTE-PM | 07-LA-101-8.0/27.3 |
Award Date | 12/19/2019 |
Closeout Date | 05/07/2024 |
Work Description | REPLACE CONCRETE BARRIERS. |
Location Description | THE CITY AND COUNTY OF LOS ANGELES FROM PILGRIMAGE OVERCROSSING TO VALLEY CIRCLE BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 08/12/2020) |
Sample Information
Sample Taken Date | 05/15/2023 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/16/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A 105793 |
The quantity of what the sample constitutes | 120 Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | 23-134 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | AAA-Irwindale | Transportation Laboratory (TL) Number | 0515C2 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 105793 |
Test Details
DIME Sample ID: 2023-05-15-32
DIME Test ID: 2023-05-15-32-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-05-17
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 05/17/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4019.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6071.5 g
Mass of HMA Sample prior to ignition: 2052.3 g
Mass Loss: 102.4 g
Mass of aggregate remaining after ignition: 1949.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.31 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.68 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/17/2023 ✔