Summary for Test 2023-04-24-48-2

Test performed: ASTM D217-16

Project Information

Project IdentifiersProject ID: 993845
DEA: 081J3604
EFIS: 0818000028
DIST-CO-RTE-PM08-SBD-215-13.9
Award Date06/27/2022
Closeout Date12/18/2023
Work DescriptionMODIFYING SIGNAL AND LIGHTING SYSTEMS, HMA AND TRAFFIC CONTROL SYSTEM.
Location DescriptionSAN BERNARDINO COUNTY IN SAN BERNARDINO AT PALM AVENUE UNDERCROSSING
QA Service Level1 (Verified on 08/02/2023)

Sample Information

Sample Taken Date04/24/2023 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2023
Sample typePer Request A brief description of the sampleAsphalt Rubber Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byVictor Last name of sampler or witnessed byCapacete
Title of sampler Telephone number of sampler
Laboratory sample identification0216-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2023-04-24-48
DIME Test ID: 2023-04-24-48-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2023-05-30

Test Results


Determination: Unworked Penetration
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 04/28/2023
Unworked Penetration: 28 0.1 mm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/30/2023