Summary for Test 2023-04-17-61-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 993122 DEA: 07322304 EFIS: 0716000054 |
---|---|
DIST-CO-RTE-PM | 07-LA-110-22.8 |
Award Date | 10/04/2021 |
Closeout Date | Not set |
Work Description | CONSTRUCT AND REPLACE BRIDGE RAILS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT FIFTH STREET OVERCROSSING AND AT SIXTH STREET OVERCROSSING |
QA Service Level | 1 (Verified on 08/04/2021) |
Sample Information
Sample Taken Date | 04/17/2023 | Sample Unique Key | 61 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2023 |
Sample type | Acceptance | A brief description of the sample | Soil for Aggregate Base |
The quantity of what the sample constitutes | 23 yd2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Rosauro | Last name of sampler or witnessed by | Nogoy |
Title of sampler | TEC | Telephone number of sampler | 2137939321 |
Laboratory sample identification | 23-0445 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Aggregate Base | A detailed description of where the material sample was collected | From various locations at Aggregate Base |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-04-17-61
DIME Test ID: 2023-04-17-61-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-05-05
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Rosauro Nogoy
Date of test: 04/17/2023
Gage No.: 60202
Test No.: no data
Nuclear By: Rosauro M Nogoy
Non-Bias Plan No.: 2
Depth: 6 in
Material No.: Imported Material
Material Type: Aggregate Base
Impact By: Rosauro M Nogoy
Standard Count Density: 2320 g/cc
Count or Density 1: 2.05 g/cc
Count or Density 2: 2.1 g/cc
Count or Density 3: 2.03 g/cc
Standard Count Moisture: 629 g/cc
Moisture Count 1: 0.15 g/cc
Moisture Count 2: 0.15 g/cc
Moisture Count 3: 0.17 g/cc
Sum of Count or Density: 6.18 g/cc
Average of Count or Density: 2.06 g/cc
Sum of Moisture Count: 0.47 g/cc
Average of Moisture Count: 0.16 g/cc
Calculated Percent Relative Compaction: 95.8 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/5/2023 ✔