Summary for Test 2023-04-18-88-1
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 215005 DEA: 044J7504 EFIS: 0416000005 |
---|---|
DIST-CO-RTE-PM | 04-ALA-84-R0.73/3.06 |
Award Date | 07/07/2022 |
Closeout Date | Not set |
Work Description | INSTALL OUTER SEPARATION BARRIERS Concrete barrier, shoulder widening, striping, cold plane and overlay. |
Location Description | ALAMEDA COUNTY IN FREMONT FROM 0.7 MILE NORTH OF SAN MATEO COUNTY LINE TO 0.1 MILE SOUTH OF TOLL PLAZA |
QA Service Level | 1 (Verified on 10/19/2020) |
Sample Information
Sample Taken Date | 04/18/2023 | Sample Unique Key | 88 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/25/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA -A |
The quantity of what the sample constitutes | 750 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Tran |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Martin Marietta - Sunol | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 4 | HMA Mix Number | L200271V |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2023-04-18-88
DIME Test ID: 2023-04-18-88-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-05-04
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Luis Magana
Date of test: 04/27/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7334.6 grams
Mass of oven-dry sample in air for Sample 1: 2531.4 grams
Mass of container filled with the sample and water for Sample 1: 8851.2 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.494
Theoretical maximum density at 25°C (77°F): 2486.8 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/4/2023 ✔