Summary for Test 2023-05-03-9-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994632 DEA: 061E6004 EFIS: 0622000067 |
---|---|
DIST-CO-RTE-PM | 06-KER-166-9.0/24.6 |
Award Date | 03/07/2023 |
Closeout Date | 02/26/2024 |
Work Description | Not set |
Location Description | FOR CONSTRUCTION ON STATE HIGHWAY IN KERN COUNTY NEAR MARICOPA FROM 4.0 MILES EAST OF BASIC SCHOOL ROAD TO ROUTE 166/99 SEPARATION |
QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 05/03/2023 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/03/2023 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA type A PG 58-16 Rsp 25% |
The quantity of what the sample constitutes | 115 | From where was the sample collected | Source |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Bown |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Solari plant Granite Arvin | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 3 | HMA Mix Number |
Test Details
DIME Sample ID: 2023-05-03-9
DIME Test ID: 2023-05-03-9-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-05-03
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 05/03/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4299.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 6546.3 g
Mass of HMA Sample prior to ignition: 2246.4 g
Mass Loss: 111.8 g
Mass of aggregate remaining after ignition: 2134.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.42 %
General comments (publicly viewable) (Max 1000 characters): L1SL3
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-1E6004_37016_230503_L1SL03_T308 | 104.70 KB | 05/03/2023 | 2023-05-03-9-1 | Info |
Test was verified on 5/3/2023 ✔