Summary for Test 2023-04-20-29-1

Test performed: ASTM A370-20

Project Information

Project IdentifiersProject ID: 993493
DEA: 100Q1224
EFIS: 1014000168
DIST-CO-RTE-PM10-MER-99-28.2/R37.3
Award Date03/30/2022
Closeout DateNot set
Work DescriptionWIDEN CONCRETE PAVEMENT LANES AND BRIDGES.
Location DescriptionMERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE
QA Service Level1 (Verified on 01/10/2022)

Sample Information

Sample Taken Date04/20/2023 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/24/2023
Sample typeQuality Assurance A brief description of the sampleCoupon Casting Sample
The quantity of what the sample constitutes264 From where was the sample collectedManufacturer
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDywidag Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)3UA
Part Number (s)68 19 216 246 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)dywidag
Prestressing Manufacturerdywidag

Test Details

DIME Sample ID: 2023-04-20-29
DIME Test ID: 2023-04-20-29-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2023-05-10

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 04/26/2023
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
13UA0.5010.19714596011059788.6aauvinen
23UA0.5010.19714594051052118.8aauvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 5/10/2023