Summary for Test 2023-03-30-7-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date03/30/2023 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/06/2023
Sample typeQuality Assurance A brief description of the sample0.6 L/R 7 wire strand
The quantity of what the sample constitutes1 From where was the sample collectedFabricator
First name of sampler or witnessed byOscar Last name of sampler or witnessed byVizcaino
Title of sampler Telephone number of sampler16787558969
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)T300720-1 Number of Coils
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)T1357375 Mfg. Lot Number(s)T300720-1
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2023-03-30-7
DIME Test ID: 2023-03-30-7-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2023-04-24

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/19/2023
UTM: 120kip
Temperature: 72 f
Extensometers: E88768
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1T1357375T300720-10.2156003055612.387.61.99bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 4/24/2023