Summary for Test 2023-04-10-51-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215183
DEA: 101C1704
EFIS: 1014000144
DIST-CO-RTE-PM10-MER-99-R12.7/17.8
Award Date01/22/2021
Closeout DateNot set
Work DescriptionRECONSTRUCT ROADWAY WITH ROADWAY EXCAVATION, PLACE HMA AND CRCP.
Location DescriptionMERCED COUNTY IN MERCED FROM 0.2 MILE SOUTH OF CHILDS AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF FRANKLIN ROAD OVERCROSSING.
QA Service Level1 (Verified on 10/20/2020)

Sample Information

Sample Taken Date04/10/2023 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2023
Sample typeQuality Assurance A brief description of the sample3/4 HMA
The quantity of what the sample constitutes12 boxes From where was the sample collectedManufacturer
First name of sampler or witnessed byTreven Last name of sampler or witnessed byFulkerson
Title of samplerLab Technician Telephone number of sampler
Laboratory sample identification23-H-39 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSanta Fe Aggregate Winton Transportation Laboratory (TL) Number032241
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number22J24A

Test Details

DIME Sample ID: 2023-04-10-51
DIME Test ID: 2023-04-10-51-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-04-19

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 04/17/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2036.0 g
Mass Loss: 104.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.73 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/19/2023