Summary for Test 2023-04-04-9-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 993184
DEA: 040A7724
EFIS: 0420000288
COOP: 042763
DIST-CO-RTE-PM04-ALA-80-6.4/6.8
Award DateNot set
Closeout DateNot set
Work DescriptionExcavation, HMA, structural concrete, minor concrete and drainage.
Location DescriptionIN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD
QA Service Level1 (Verified on 04/08/2022)

Sample Information

Sample Taken Date04/04/2023 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/04/2023
Sample typeQuality Assurance A brief description of the sample3/4" HMA HOT MIX
The quantity of what the sample constitutes2 boxes From where was the sample collectedManufacturer
First name of sampler or witnessed byMattew Last name of sampler or witnessed byJames
Title of samplerQC Manager Telephone number of sampler14158478087
Laboratory sample identificationRich_23_ 79 Linked DIME Sample ID2023-04-04-6
The fabricator/manufacturer/facility nameDutra Materials Richmond Transportation Laboratory (TL) NumberC727176
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number2
Sublot number1 HMA Mix NumberL210140WMA

Test Details

DIME Sample ID: 2023-04-04-9
DIME Test ID: 2023-04-04-9-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-04-05

Test Results


Number of Samples: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Nick Hall
Date of test: 04/05/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7391.8 grams
Mass of oven-dry sample in air for Sample 1: 2591.0 grams
Mass of container filled with the sample and water for Sample 1: 8916.4 grams
Mass of container filled with water 2: 7391.8 grams
Mass of oven-dry sample in air for Sample 2: 2606.0 grams
Mass of container filled with the sample and water for Sample 2: 7391.8 grams
Temperature of Water: 8926 °F
Specific Gravity for Sample 1: 2.430
Specific Gravity for Sample 2: 1.000
Average Specific Gravity: 1.715
Theoretical maximum density at 25°C (77°F): 1710 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Lot 2 SL 1

Test was verified on 4/5/2023