Summary for Test 2022-10-06-92-1
Test performed: ASTM C1260-14Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/06/2022 | Sample Unique Key | 92 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/06/2022 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
The quantity of what the sample constitutes | 5 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Russ | Last name of sampler or witnessed by | Fisher |
Title of sampler | Quality Control Supervisor | Telephone number of sampler | |
Laboratory sample identification | Twining, Incorporated - Long Beach | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Hi Grade Material Oro Grande/AGCON | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0046 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2022-10-06-92
DIME Test ID: 2022-10-06-92-1
Testing Lab: Hi Grade Materials
Test Method: ASTM C1260-14: Standard Test Method for Potential Alkali Reactivity of Aggregates (Mortar-Bar Method)
Test Release Date: 2023-04-03
Test Results
Input Type: Calculated
Tester's full name: Ali Erbektas
Date of test: 10/06/2022
Type and source of aggregate: washed concrete sand
Type and source of Portland cement: Calportland, Oro Grande
Alkali content of cement as percent potassium oxide: 0.48
Alkali content of cement as percent sodium oxide: 0.48
Alkali content of cement as percent calculated sodium oxide: 0.48
Comments about aggregate preparation: no data
Comments about specimen features: no data
Amount of mixing water: 1N NaOH
Average percent change in length (zero reading): 0.0000 %
Average percent change in length (first reading): 0.0200 %
Average percent change in length (second reading): 0.0300 %
Average percent change in length (third reading): 0.0500 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2023 ✔