Summary for Test 2023-03-20-5-4
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 994401 DEA: 09379304 EFIS: 0919000007 |
---|---|
DIST-CO-RTE-PM | 09-INY-127-21.0/34.5,41.8/49.4 |
Award Date | 01/23/2023 |
Closeout Date | 12/27/2023 |
Work Description | PARTIAL DEPTH RECYCLE AND HOT MIX ASPHALT (TYPE A). |
Location Description | INYO COUNTY NEAR SHOSHONE FROM 4.6 MILES NORTH OF ROUTE 178 WEST TO 7.6 MILES SOUTH OF ROUTE 190 AND FROM 0.3 MILE SOUTH OF ROUTE 190 TO NEVADA STATE LINE |
QA Service Level | 1 (Verified on 08/02/2023) |
Sample Information
Sample Taken Date | 03/20/2023 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/20/2023 |
Sample type | Verification | A brief description of the sample | 3/4" Coldfeed |
The quantity of what the sample constitutes | Tons | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Young |
Title of sampler | TET | Telephone number of sampler | 7609208859 |
Laboratory sample identification | JMF-3 | Linked DIME Sample ID | 2023-03-20-4 |
The fabricator/manufacturer/facility name | Wulfenstein Construction | Transportation Laboratory (TL) Number | 09 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Wulfenstein Construction |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Hot Plant Belt Cut | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-03-20-5
DIME Test ID: 2023-03-20-5-4
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2023-04-03
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 03/22/2023
Mass of measure: 189.3 grams
Bulk dry specific gravity: 2.667
Mass of sample and measure #1: 334.5 grams
Mass of sample and measure #2: 334.8 grams
Volume of cylinder: 100 mL
Mass of sample #1: 145.2 grams
Mass of sample #2: 145.5 grams
Uncompacted voids #1: 45.6 %
Uncompacted voids #2: 45.4 %
Average uncompacted voids: 45.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2023 ✔