Summary for Test 2023-03-31-8-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994078 DEA: 060X7604 EFIS: 0618000129 |
---|---|
DIST-CO-RTE-PM | 06-KER-119-0.2/0.6 |
Award Date | 09/26/2022 |
Closeout Date | 04/08/2024 |
Work Description | INSTALL LEFT-TURN CHANNELIZATIONS, CONSTRUCT WIDENING, RHMA OVERLAY. |
Location Description | KERN COUNTY IN TAFT FROM 0.1 MILE NORTH OF GARDNER FIELD ROAD TO 0.5 MILE SOUTH OF ASH STREET |
QA Service Level | 1 (Verified on 07/11/2022) |
Sample Information
Sample Taken Date | 03/31/2023 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/31/2023 |
Sample type | Acceptance | A brief description of the sample | Native Material |
The quantity of what the sample constitutes | 40 lbs | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Neale | Last name of sampler or witnessed by | Brown |
Title of sampler | TESTER | Telephone number of sampler | 6615498281 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | EB Hwy 119 sta 55+60 to 62+90 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Test holes at jobsite | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-03-31-8
DIME Test ID: 2023-03-31-8-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-03-31
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Neale Brown
Date of test: 03/31/2023
Gage No.: 30699
Test No.: 1
Nuclear By: Neale Brown
Non-Bias Plan No.: 4- even
Depth: 6
Material No.: no data
Material Type: silty F-C sand, light brown
Impact By: Neale Brown
Standard Count Density: 1944 g/cc
Count or Density 1: 2116 g/cc
Count or Density 2: 1947 g/cc
Count or Density 3: 1617 g/cc
Count or Density 4: 1895 g/cc
Count or Density 5: 1771 g/cc
Standard Count Moisture: 623 g/cc
Moisture Count 1: 195 g/cc
Moisture Count 2: 198 g/cc
Moisture Count 3: 178 g/cc
Moisture Count 4: 192 g/cc
Moisture Count 5: 187 g/cc
Sum of Count or Density: 9346.00 g/cc
Average of Count or Density: 1869.00 g/cc
Sum of Moisture Count: 950.00 g/cc
Average of Moisture Count: 190.00 g/cc
Count Ratio Density: 0.96
Count Ratio Moisture: 0.30
Calculated Percent Relative Compaction: 100 %
Reported Percent Relative Compaction: 100 %
General comments (publicly viewable) (Max 1000 characters): EB Hwy 119 Sta 55+60 to 62+90 elevaton 2' BFG width 8'-17' 6" probe
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06_0x7604_37000_220331_01_CTM231_216 | 119.40 KB | 03/31/2023 | 2023-03-31-8-1 | Info |
Test was verified on 3/31/2023 ✔