Summary for Test 2023-03-24-19-2
Test performed: AASHTO T210-15Project Information
Project Identifiers | Project ID: 993301 DEA: 060U2804 EFIS: 0615000293 |
---|---|
DIST-CO-RTE-PM | 06-TUL-245-1.4,4.2 |
Award Date | 01/03/2022 |
Closeout Date | Not set |
Work Description | PRECAST PRESTRESSED CONCRETE BOX GIRDER AND SLAB, BRIDGE REMOVAL. |
Location Description | TULARE COUNTY NEAR WOODLAKE AT YOKOHL CREEK BRIDGE AND AT KAWEAH RIVER BRIDGE |
QA Service Level | 1 (Verified on 10/11/2021) |
Sample Information
Sample Taken Date | 03/24/2023 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/24/2023 |
Sample type | Quality Assurance | A brief description of the sample | HMA 3/4" PG70-10 22-J-026 |
The quantity of what the sample constitutes | 147 tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Ruiz |
Title of sampler | Consultant Tester | Telephone number of sampler | 5592890420 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Porterville Asphalt PAI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Kaweah- Yokohl Bridges Wood Land |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | 1 | |
Sublot number | 3 | Aggregate Mix Number | SL3 |
Test Details
DIME Sample ID: 2023-03-24-19
DIME Test ID: 2023-03-24-19-2
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2023-03-29
Test Results
Which test procedure(s) is/are used?: Procedure A
Input Type: Calculated
Tester's full name: Doug Ruff
Date of test: 03/24/2023
Was strict temperature control maintained?: No
What type of water was used?: Distilled
Durability Index (coarse): 80
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/29/2023 ✔