Summary for Test 2023-03-08-11-2

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date03/08/2023 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing03/08/2023
Sample typeQuality Assurance A brief description of the sampleHRC 150 T-Heads
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byTimber Last name of sampler or witnessed byLoveland
Title of samplerQuality Assurance Inspector Telephone number of sampler4355538344
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL170-039-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)6037673 Head Manufacturer Lot Number(s)100011558541
Rebar Size#11 Headed Bar Model NameHRC 120 T Heads
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerNucor
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-03

Test Details

DIME Sample ID: 2023-03-08-11
DIME Test ID: 2023-03-08-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-03-22

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 03/21/2023
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
111.5615395498689Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 3/22/2023