Summary for Test 2023-01-27-40-1
Test performed: ASTM C42-13
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 994464 DEA: 042Y8804 EFIS: 0423000169 |
---|---|
DIST-CO-RTE-PM | 04-SON-12-15.382/15.382 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 01/17/2023) |
Sample Information
Sample Taken Date | 01/27/2023 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/21/2023 |
Sample type | Acceptance | A brief description of the sample | Rapid Strength Concrete Type III |
The quantity of what the sample constitutes | 36 CY | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Lauren | Last name of sampler or witnessed by | Lau |
Title of sampler | Assistant Structure Representative | Telephone number of sampler | 5103939262 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Ghilotti Brothers | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 20-0203R/L | |
Structure name | Hwy 12, Dutton Bridge, Approach Slab Northeast, Lane 2 |
Material Information
Material Type | Concrete Core | Detail description | Approach slab lane 2 |
---|---|---|---|
Structure names | Hwy 12 Dutton bridge approach slab | Type of material | Rapid strength concrete Type III |
Test Details
DIME Sample ID: 2023-01-27-40
DIME Test ID: 2023-01-27-40-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C42-13: Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete
Test Release Date: 2023-03-21
Test Results
Input Type: Measured
Tester's full name: Spencer Adams
Date of test: 03/21/2023
Cross Sectional Area: 12.13
Maximum Load: 100025
Length of Core: 5.79
Diameter of Core: 3.93
Type of Fracture: 1
Age of Specimen: 1
L/D Ratio: 1.47
Compressive Strength: 8246
Correction Factor: 0.957
Corrected Strength: 7890
Calculated Density: 0
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/21/2023 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.