Summary for Test 2023-03-08-48-5
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 993347 DEA: 07335304 EFIS: 0716000363 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-42.3/48.3 |
Award Date | 12/23/2021 |
Closeout Date | 11/25/2024 |
Work Description | PLACE CIDH CONCRETE PILES, FURNISH AND INSTALL SIGN STRUCTURES. |
Location Description | LOS ANGELES COUNTY IN SAN DIMAS, POMONA AND CLAREMOUNT FROM 0.2 MILE WEST OF KELLOGG DRIVE UNDERCROSSING TO THE SAN BERNARDINO COUNTY LINE |
QA Service Level | 1 (Verified on 12/06/2021) |
Sample Information
Sample Taken Date | 03/08/2023 | Sample Unique Key | 48 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/10/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 PCC Aggregates |
The quantity of what the sample constitutes | 30 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cemex -Fontana | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0040 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | sign structure foundation | The fabricator/manufacturer designation for the sample | Mix 1610974 |
The plant number | Fontana | A detailed description of where the material sample was collected | Stockpile @ Plant |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | 1610974 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-03-08-48
DIME Test ID: 2023-03-08-48-5
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-03-30
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 03/10/2023
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
512 grams | ||||||
0.0 grams | 100 % | |||||
13.0 grams | 97 % | |||||
132.0 grams | 74 % | |||||
240.0 grams | 53 % | |||||
339.0 grams | 34 % | |||||
429.0 grams | 16 % | |||||
477.0 grams | 7 % | |||||
500.0 grams | 2 % | |||||
501.0 grams |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/30/2023 ✔