Summary for Test 2023-03-07-26-5

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date03/07/2023 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/09/2023
Sample typeAcceptance A brief description of the sample3/8 & Sand
The quantity of what the sample constitutes60 cy From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler2137924794
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons - Pomona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0061
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sampleMix RRM 17066
The plant numberPomona A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberRRM17066 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-03-07-26
DIME Test ID: 2023-03-07-26-5
Testing Lab: CT D07 - Plant Services
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2023-03-17

Test Results


Input Type: Measured
Tester's full name: Victor Pham
Date of test: 03/09/2023
Wet weight of the sample: 1100.0000000000 grams
Dry weight of the sample: 1026.0000000000 grams
Weight of water in sample: 74.0000000000 grams
Percent moisture: 7.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/17/2023