Summary for Test 2023-01-30-60-2

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 993717
DEA: 021J8304
EFIS: 0220000148
DIST-CO-RTE-PM02-SHA,TEH-5,36,44-VAR
Award Date06/15/2022
Closeout Date05/06/2024
Work DescriptionREINF STRUCTURAL CONC BRIDGE, APPROACH SLAB & POLYESTER CONC OVERLAY.
Location DescriptionSHASTA AND TEHAMA COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date01/30/2023 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/15/2023
Sample typePer Request A brief description of the sampleStainless Steel Headed Bars
The quantity of what the sample constitutes12 From where was the sample collectedFabricator
First name of sampler or witnessed byEric Last name of sampler or witnessed byChaffee
Title of samplerStructures Representative Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameContractors Materials Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)V74Y Head Manufacturer Lot Number(s)H21F
Rebar Size#5 Headed Bar Model NameTerminator
Size of HeadReduced Size - 4x Head Connection TypeThreaded
Head ShapeCircular Rebar ManufacturerNorth American Stainless
Head ManufacturerContractors Materials Company Head FabricatorContractors Materials Company
Material Standard CodeASTM A955 Headed Bar Unique IDNot on AML

Test Details

DIME Sample ID: 2023-01-30-60
DIME Test ID: 2023-01-30-60-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-03-09

Test Results


Number of Headed Bar Samples: 11
Input Type: Measured
Tester's full name: She Vang
Date of test: 03/01/2023
UTM: 400KIP
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
1Sample 60.3133907109377Failed in affected zone Yield at 91418 psibewing
2Sample 70.3133592108360Failed in affected zone Yield at 95231 psibewing
3Sample 8 0.3131653102106Failed in affected zone Yield at 90184 psibewing
4Sample 9 0.3133948109511Failed in affected zone Yield at 69019 psibewing
5Sample 10 0.3133968109576Failed in affected zone Yield at 96224 psibewing
6Sample 110.3134463111171Failed in affected zone Yield at 91163 psibewing
7Sample 12 0.3133981109616Failed in affected zone Yield at 91072 psirmacias
8Sample 10.3132018103283Failed in affected zone Yield at 96416 psirmacias
9Sample 2 0.313057198617Failed in affected zone Yield at 82029 psirmacias
10Sample 3 0.3134068109897Broke in affected zone Yield at 84447 psirmacias
11Sample 4 0.3133439107866Failed in affected zone Yield at 83784 psirmacias

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/9/2023