Summary for Test 2023-03-01-2-13

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout DateNot set
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date03/01/2023 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/03/2023
Sample typeQuality Assurance A brief description of the sampleHRC 150 T-Heads
The quantity of what the sample constitutesQty 2032 HRC150 T heads From where was the sample collectedFabricator
First name of sampler or witnessed byHenry Last name of sampler or witnessed byArredondo
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler5623329603
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameHRC Fountain Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL166-017-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3118273 Head Manufacturer Lot Number(s)400000945421
Rebar Size#9 Headed Bar Model NameHRC 150 T Heads
Size of HeadFull Size - 9x Head Connection Type
Head ShapeCircular Rebar ManufacturerCMC Steel Texas
Head Manufacturernucor cold finish utah Head FabricatorHRC Fountain Valley
Material Standard CodeASTM A706 Headed Bar Unique ID9FW-17-04

Test Details

DIME Sample ID: 2023-03-01-2
DIME Test ID: 2023-03-01-2-13
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-03-06

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 03/06/2023
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
11319518995189Ok Neckingspaine

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 3/6/2023