Summary for Test 2023-02-21-47-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 993301 DEA: 060U2804 EFIS: 0615000293 |
---|---|
DIST-CO-RTE-PM | 06-TUL-245-1.4,4.2 |
Award Date | 01/03/2022 |
Closeout Date | Not set |
Work Description | PRECAST PRESTRESSED CONCRETE BOX GIRDER AND SLAB, BRIDGE REMOVAL. |
Location Description | TULARE COUNTY NEAR WOODLAKE AT YOKOHL CREEK BRIDGE AND AT KAWEAH RIVER BRIDGE |
QA Service Level | 1 (Verified on 10/11/2021) |
Sample Information
Sample Taken Date | 02/21/2023 | Sample Unique Key | 47 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/02/2023 |
Sample type | Quality Assurance | A brief description of the sample | Asphalt Binder PG 70-10 |
The quantity of what the sample constitutes | 1 can of binder | From where was the sample collected | Source |
First name of sampler or witnessed by | Hoidos | Last name of sampler or witnessed by | Haddedin |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refining Co Inc | Transportation Laboratory (TL) Number | C804597 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | storage tank | |
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-02-21-47
DIME Test ID: 2023-02-21-47-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-03-03
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 03/03/2023
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.142 kPa
Phase Angle (δ) (for the 10 cycles): 89.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.186 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 1.19 kPa
General comments (publicly viewable) (Max 1000 characters): original
Test was verified on 3/3/2023 ✔