Summary for Test 2023-01-27-22-3

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date01/27/2023 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/27/2023
Sample typeQuality Control A brief description of the sample3x6 Cylinders
The quantity of what the sample constitutesConcrete Cylinders From where was the sample collectedJob Site
First name of sampler or witnessed bySpencer Last name of sampler or witnessed byAdams
Title of samplerMREA Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameMix 3

Material Information

Material TypeConcrete The concrete mix design numberHQ Conc Lab Mix 4
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedMix 4
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedMixer Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-01-27-22
DIME Test ID: 2023-01-27-22-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-02-17

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 02/17/2023
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 3.01 in
Average diameter of cylinder 2: 3.01 in
Maximum load on cylinder 1: 9412 lbf
Maximum load on cylinder 2: 8773 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 21 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 7.12 in^2
Cross sectional area of cylinder 2: 7.12 in^2
Compressive strength of cylinder 1: 1323.0 psi
Compressive strength of cylinder 2: 1233.0 psi
Compressive strength (to nearest 10 psi): 1280 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Cylinder Code 1 of 2

Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 2

Test was verified on 2/17/2023