Summary for Test 2023-01-26-63-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 994489 DEA: 010K6904 EFIS: 0120000135 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-M0/46.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/25/2023) |
Sample Information
Sample Taken Date | 01/26/2023 | Sample Unique Key | 63 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/13/2023 |
Sample type | Verification | A brief description of the sample | APC Determination |
The quantity of what the sample constitutes | NA | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Tom | Last name of sampler or witnessed by | Brown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CR20230071 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | 01-DN-101-0.0-46.5 | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-01-26-63
DIME Test ID: 2023-01-26-63-1
Testing Lab: CT HQ - FFS - Corrosion Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2023-02-16
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Payam Vosoughi
Date of test: 02/15/2023
Minimum soil resistance of the lab measurement: 1182 Ohms
Soil sample temperature: 21.4 C
Soil box constant: 5
pH of soil: 5.37
Minimum soil resistance corrected to 15.5: 1356.34 Ohm-cm
Minimum soil resistivity at 15.5: 6782 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/16/2023 ✔