Summary for Test 2023-01-18-25-2
Test performed: AASHTO T48-18Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/18/2023 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/18/2023 |
Sample type | Quality Control | A brief description of the sample | Tank 2001 |
The quantity of what the sample constitutes | 1 of 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Molly | Last name of sampler or witnessed by | Gibney |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | AC-3008 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | West Sacramento,CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | VSS Emultech - West Sacramento CA | Multigrade | Yes |
Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-01-18-25
DIME Test ID: 2023-01-18-25-2
Testing Lab: VSS Emultech - West Sacramento
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2023-02-15
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Molly Gibney
Date of test: 01/19/2023
Observed Flash Point: 300 C
Ambient Barometric Pressure: 756 mmHg
Cleveland Open-Cup Flash Point in Celsius: 300 C
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/15/2023 ✔